Heating method
- Features
-
“Double-sided heating method", composed of upper and lower heater box
(External emit when machine stop or an emergency)
- Heater specification
- Infrared ceramic heater (electric power 400W, size 122mm x 122mm)
- Heater Box
- Width 1,080mm x Length 2,700mm (for both Upper and Lower)
- Temperature control
- SSR (Solid state relay) using P.I.D. automatic temperature compensation and “ON, OFF” temperature control method on touch monitor Can save temperature data for each forming product.
- Control point
- Upper heater 73 point, Lower heater 37 point (Upper and Lower Total : 110 points)